TY - JOUR
T1 - Protection against ionizing radiation by leaded glass googles during interventional cardiology
AU - Zett-Lobos, Claudio
AU - Vera-Muñoz, Felipe
AU - Arriola-Alvarez, Katerina
AU - Díaz-Ramos, Oscar
AU - Gamarra, Jorge
AU - Fernández-Palomo, Cristian
AU - Merello, Lorenzo
AU - Mora, Alex D.
AU - Gutiérrez, Alejandro
AU - Catalán-Reyes, Mónica
AU - Ramos-Avasola, Sergio
PY - 2013
Y1 - 2013
N2 - Background: It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP). Aim: To assess if the degree of attenuation of the secondary ionizing radiation achieved by the use of 0.25 mm Pb leaded glass goggles, in occupationally exposed workers in interventional cardiology procedures, meets the latest ICRP recommendations. Material and Methods: A prospective investigation was carried out to compare the eye exposure to secondary ionizing radiation received by occupationally exposed personnel in a 9 months period. A set of two thermo luminescent dosimeters was arranged in the front and back of leaded glass goggles in a cohort of seven members of an interventional cardiology service, exposed to 1057 consecutive procedures. Results: The monthly dose equivalent measurement performed in front of the goggles ranged between 1.1 and 6.5 mSv, for paramedics and interventional cardiologists. The radiation measured in the back of the glass varied between 0.66 and 2.75 mSv, respectively. The degree of attenuation of the dose at eye level ranged from 40% to 57.7%, respectively. The projected annual exposure would reach 33 mSv for the interventional cardiologist. Conclusions: With a similar load of work and wearing 0.25 mm Pb equivalent glass goggles, interventional cardiologists will exceed the crystalline equivalent dose limit recommended by the ICRP (20 mSv/year averaged over the past 5 years).
AB - Background: It is not known whether leaded glass goggles with 0.25 mm Pb equivalency, used in interventional cardiology procedures, attenuate radiation below the levels established by the latest recommendation of the International Commission on Radiological Protection (ICRP). Aim: To assess if the degree of attenuation of the secondary ionizing radiation achieved by the use of 0.25 mm Pb leaded glass goggles, in occupationally exposed workers in interventional cardiology procedures, meets the latest ICRP recommendations. Material and Methods: A prospective investigation was carried out to compare the eye exposure to secondary ionizing radiation received by occupationally exposed personnel in a 9 months period. A set of two thermo luminescent dosimeters was arranged in the front and back of leaded glass goggles in a cohort of seven members of an interventional cardiology service, exposed to 1057 consecutive procedures. Results: The monthly dose equivalent measurement performed in front of the goggles ranged between 1.1 and 6.5 mSv, for paramedics and interventional cardiologists. The radiation measured in the back of the glass varied between 0.66 and 2.75 mSv, respectively. The degree of attenuation of the dose at eye level ranged from 40% to 57.7%, respectively. The projected annual exposure would reach 33 mSv for the interventional cardiologist. Conclusions: With a similar load of work and wearing 0.25 mm Pb equivalent glass goggles, interventional cardiologists will exceed the crystalline equivalent dose limit recommended by the ICRP (20 mSv/year averaged over the past 5 years).
KW - Lens, crystalline
KW - Radiation dosage
KW - Radiology, interventional
UR - http://www.scopus.com/inward/record.url?scp=84878160711&partnerID=8YFLogxK
U2 - 10.4067/S0034-98872013000100009
DO - 10.4067/S0034-98872013000100009
M3 - Article
C2 - 23732416
AN - SCOPUS:84878160711
SN - 0034-9887
VL - 141
SP - 63
EP - 69
JO - Revista Medica de Chile
JF - Revista Medica de Chile
IS - 1
ER -